Skip to content
SL Tiling

Residential

Underfloor Heating Installation in Auckland

Cable set out to the furniture plan, resistance tested at every stage, sensor in a conduit.

The work

Electric underfloor heating is cheap to install and expensive to repair, because the repair is the floor. Almost every failure traces back to three things: a cable damaged during the tiling, a sensor that cannot be replaced, and a mat run under a vanity where nobody stands.

Set out to the furniture plan

Heating goes where feet go. We set the mat out around the vanity footprint, the toilet pan and the shower hob, so you are not paying to warm the underside of cabinetry for the next fifteen years.

Resistance tested three times

Cable resistance and insulation are tested on arrival, after laying, and after tiling, and each reading is recorded. A reading that moves tells you exactly which trade to talk to, while the floor is still accessible.

Sensor in a conduit

The floor sensor goes inside a conduit that terminates at the thermostat, so a failed sensor is a five-minute swap rather than a demolished floor. It is a ten-dollar detail that decides a four-thousand-dollar outcome.

Encapsulated, then tiled

Cable is embedded in levelling compound or a screed before tiling rather than being bedded straight into adhesive. It protects the cable from the trowel and gives an even heat spread.

What the price covers

  • Heat-loss and coverage assessment against the room layout
  • Set-out around fixed joinery and sanitaryware
  • Insulation board where the slab would otherwise absorb the heat
  • Cable or mat installation with recorded resistance testing
  • Floor sensor installed in a replaceable conduit
  • Encapsulation in levelling compound or screed
  • Coordination with the electrician for thermostat connection
  • Commissioning record and controlled first heat-up

Standards applied

  • AS 3958.1
  • NZBC E3

We reply to every quote request within one working day.

Request a measured quote

What this work looks like

Crew trowelling and levelling a screed bed across a deck
Notched adhesive bed and a levelling spacer beside a large-format tile
Newly completed room with a large-format porcelain floor and flush skirting junction
Ensuite tiled floor-to-ceiling in warm grey porcelain around a freestanding bath

Questions

Underfloor heating, answered

We reply to every quote request within one working day. If your question is not here, ask it on the quote form and you will get a written answer, not a sales call.

Ask your question

Start your project

Tell us the room. We will tell you the number

We reply to every quote request within one working day. Measured quotes are fixed and written, broken down by area, with tile allowances and movement joints itemised.